Conventional coal-fired power plant

From Citizendium
Revision as of 16:30, 8 December 2008 by imported>Milton Beychok (→‎Control of mercury emissions: Added references)
Jump to navigation Jump to search
This article is developing and not approved.
Main Article
Discussion
Related Articles  [?]
Bibliography  [?]
External Links  [?]
Citable Version  [?]
Gallery [?]
 
This editable Main Article is under development and subject to a disclaimer.
(CC) Photo: Daniel Ullrich
Coal-fired power plant in Voerde, Germany

A conventional coal-fired power plant produces electricity by burning coal in a steam generator that heats water to produce high pressure steam. The steam flows through a series of steam turbines which spin an electrical generator to produce electricity. The exhaust steam from the turbines is cooled, condensed back into water, and returned to the steam generator to start the process over.

Conventional coal-fired power plants are highly complex and custom designed on a large scale for continuous operation 24 hours per day and 365 days per year. Such plants provide most of the electrical energy used in many countries.

Coal transport and delivery

Coal is delivered by highway truck, rail, barge or collier ship. Some plants are even built near coal mines and the coal is delivered from the mines by conveyors or by massive trucks.

A large coal train called a "unit train" may be two kilometers (over a mile) long, containing 100 railcars with 90 metric tons in each one, for a total load of 9,000 metric tons. A large plant under full load requires at least one coal delivery this size every day. Plants may get as many as three to five trains a day, especially in "peak season", during the summer months when power consumption is high. A large coal-fired power plant such as the one in Nanticoke, Canada stores several million metric tons of coal for winter use when delivery via the Great Lakes is not possible.

Modern unloaders use rotary dump devices, which eliminate problems with coal freezing in bottom dump cars. The unloader includes a train positioner arm that pulls the entire train to position each car over a coal hopper. The dumper clamps an individual car against a platform that swivels the car upside down to dump the coal. Swiveling couplers enable the entire operation to occur while the cars are still coupled together. Unloading a unit train takes about three hours.

Shorter trains may use railcars with an "air-dump", which relies on air pressure from the engine plus a "hot shoe" on each car. This "hot shoe" when it comes into contact with a "hot rail" at the unloading trestle, shoots an electric charge through the air dump apparatus and causes the doors on the bottom of the car to open, dumping the coal through the opening in the trestle. Unloading one of these trains takes anywhere from an hour to an hour and a half. Older unloaders may still use manually operated bottom-dump rail cars and a "shaker" attached to dump the coal.

A collier (cargo ship carrying coal) may hold 35,000 metric tons of coal and takes several days to unload. Colliers are large, seaworthy, self-powered ships. For transporting coal in calmer waters, such as rivers and lakes, flat-bottomed vessels called barges pulled by towboats are used.

For startup or auxiliary purposes, a coal-fired power plant may use fuel oil as well. Fuel oil can be delivered to plants by pipeline, tanker, tank car or truck.

Fuel processing

Coal is prepared for use by first crushing the rough coal into pieces less than 5 cm in size. The coal is then transported from the storage yard to in-plant storage silos by rubberized conveyor belts.

In plants that burn pulverized coal, coal from the storage silos is fed into pulverizers ) that grind the crushed coal into the consistency of face powder and mix it with primary combustion air which transports the pulverized coal to the steam generator furnace. A 500 MW coal-fired power plant will have about six such pulverizers, five of which will supply the steam generator at full load with about 225 metric tons per hour.

In plants that do not burn pulverized coal, the crushed coal may be directly fed into cyclone burners, a specific kind of combustor that can efficiently burn larger pieces of coal.

Feedwater heating and deaeration

For more information, see: Boiler feedwater heater and Deaerator.

The feedwater used in the steam generator consists of recirculated condensate water and makeup water. Because the metallic materials it contacts are subject to corrosion at high temperatures and pressures, the makeup water is highly purified in a system of water softeners and ion exchange demineralizers. The makeup water in a 500 MW plant amounts to about 75 litres per minute to offset the small losses from steam leaks in the system.

(PD) Image: Milton Beychok
Diagram of a tray-type boiler feed water deaerator (with vertical, domed aeration section and horizontal water storage section

The feedwater system begins with the condensate water being pumped out of the turbine exhaust steam condenser (commonly referred to as a surface condenser). The condensate water flow rate in a 500 MW coal-fired power plant is about 23,000 litres per minute.

The feedwater plus makeup water flows through intermediate feedwater heaters heated with steam extracted from the steam turbines. Typically, the total feedwater then flows through a deaerator[1][2] that removes dissolved air from the water, further purifying and reducing its corrosivity.

Following the deaeration, the water may be dosed with hydrazine, a chemical that removes the remaining oxygen in the water to below 5 parts per billion (ppb). It is also dosed with pH control agents such as ammonia or morpholine to keep the residual acidity low and thus non-corrosive.

The steam generator

(PD) Image: Milton Beychok
Simplified diagram of a conventional coal-fired steam generator.

A conventional coal-fired steam generator is a rectangular furnace about 15 metres on a side and 40 metres tall. Its walls are made of a web of high pressure steel boiler tubes.

The deaerated boiler feedwater enters the economizer (see the adjacent diagram) where it is preheated by the hot combustion flue gases and then flows into the boiler steam drum at the top of the furnace. Water from that drum circulates through the tubes in the furnace walls.

Pulverized coal is air-blown into the furnace from fuel nozzles at the four corners and it rapidly burns, forming a large fireball at the center. The thermal radiation of the fireball heats the water that circulates through the boiler tubes in the furnace walls. As the water circulates, it absorbs heat and partially changes into steam at about 362 °C and 190 bar (19 MPa). In the boiler steam drum, the steam is separated from the circulating water. The steam then flow through superheat tubes that hang in the hottest part of the combustion flue gases as they exit the furnace. Here the steam is superheated to about 540 °C before being routed into the high pressure steam turbine.

The steam turbines and the electrical generator

(CC) Photo: Siemens AG, Germany
Rotor of a large modern steam turbine, used in a power plant.

The staged series of steam turbines includes a high pressure steam turbine, an intermediate steam pressure turbine and two low pressure steam turbines. The series of turbines are interconnected to each other and are on a common shaft, with the electrical generator also being on that common shaft.

As steam moves through the system and loses pressure and thermal energy it expands in volume, requiring increasing turbine diameter and longer turbine blades at each succeeding stage. The entire rotating mass may be over 180 metric tons and 30 metres long. It is so heavy that it must be kept turning slowly even when shut down (at 3 rpm) so that the shaft will not bow even slightly and become unbalanced. This is so important that it is one of only major functions to be maintained by the emergency power batteries on site.

Superheated steam from the steam generator flows into the high pressure turbine. The exhaust steam from the high pressure turbine (reduced in pressure and in temperature) returns to the steam generator's reheating tubes where it is reheated back to 540 °C before it flows into the intermediate pressure turbine. The exhaust steam from the intermediate pressure turbine flow directly into the low pressure turbine and the exhaust steam from the low pressure turbines flows into the surface condenser.

The turbine-driven electrical generator, about 10 metres long and 4 metres in diameter, contains a stationary stator and a spinning rotor. In operation, it generates up to 21,000 amperes at 24,000 volts of alternating current (about 500 MW) as it spins at about 3,000 or 3,600 rpm, synchronized to the power grid.

The rotor spins in a sealed chamber cooled with hydrogen gas, selected because it has the highest known heat transfer coefficient of any gas and for its low viscosity which reduces windage losses. This system requires special handling during startup, with air in the chamber first displaced by carbon dioxide before filling with hydrogen. This ensures that a highly explosive hydrogen-oxygen environment is not created.

The power grid frequency is 60 Hz across North America and 50 Hz in Europe, Oceania, Asia (Korea and parts of Japan are notable exceptions) and parts of Africa.

The electricity flows to a distribution yard where transformers step the voltage up to 115, 230, 500 or 765 kV as needed for transmission to its destination.

Steam condensing and cooling towers

For more information, see: Surface condenser and Cooling tower.
(GNU) Image: Milton Beychok
Diagram of a typical water-cooled surface condenser.

The exhaust steam from the low pressure turbines is condensed into water in a water-cooled surface condenser. The condensed water is commonly referred to as condensate. The surface condenser operates at an absolute pressure of about 35 to 40 mmHg (i.e., a vacuum of about 720 to 725 mmHg) which maximizes the overall power plant efficiency.

The surface condenser is usually a shell and tube heat exchanger. Cooling water circulates through the tubes in the condenser's shell and the low pressure exhaust steam is condensed by flowing over the tubes as shown in the adjacent diagram. Typically the cooling water causes the steam to condense at a temperature of about 35 °C. The lower is the condensing temperature, the lower is the vacuum at the exhaust of the low pressure turbine and the higher is the overall plant efficiency. The limiting factor in providing a low condensing temperatures is the temperature of the cooling water and that, in turn, is limited by the prevailing average climatic conditions at the power plant's location.

The condensate from the bottom of the surface condenser is pumped back to be reused as feedwater to the steam generator.

(GNU) Photo: Stefan Kühn
Hyperboloid cooling towers (with water vapor plumes).
(PD) Photo: Tennessee Valley Authority
Rectangular, mechanically induced draft cooling towers (with water vapor plumes).

The heat absorbed by the circulating cooling water in the condenser tubes must also be removed to maintain the ability of the water to cool as it circulates. This is done by pumping the warm water from the condenser through either natural draft, forced draft or induced draft cooling towers (as seen in the images to the right) that reduce the temperature of the water by about 11–17 °C and expel the low-temperature waste heat to the atmosphere. The circulation flow rate of the cooling water in a 500 MW unit is about 14.2 m³/s (225,000 US gal/minute) at full load.[3]

The condenser tubes are made of brass or stainless steel to resist corrosion from either side. Nevertheless they may become internally fouled during operation by bacteria or algae in the cooling water or by mineral scaling, all of which inhibit heat transfer and reduce the condenser efficiency. Many plants include an automatic cleaning system that circulates sponge rubber balls through the tubes to scrub them clean without the need to take the system off-line.

The cooling water used to condense the steam in the condenser returns to its source without having been changed other than having been warmed. If the water returns to a local water body (rather than a circulating cooling tower), it is mixed with cool raw water to lower its temperature and prevent thermal shock to aquatic biota when discharged into that body of water.

Another form of condensing system is the air-cooled condenser. Exhaust heat from the low pressure section of a steam turbine flows through the air-cooled condensing tubes which are usually finned and ambient air is directed over the fins by a large fan. Air-cooled condensers typically operate at a higher temperature than water-cooled surface condensers. While reducing the amount of water used in a power plant, air-cooled condensers reduce the efficiency of the power plant.

Diagram of the overall conventional coal-fired power plant

Simplified coal-fired power plant
1. Cooling tower 11. High pressure steam turbine 20. Fan
2. Cooling water pump 12. Deaerator 21. Reheater
3. Three-phase transmission line 13. Feedwater heater 22. Combustion air intake
4. Step-up transformer 14. Coal conveyor 23. Economiser
5. Electrical generator 15. Coal hopper 24. Air preheater
6. Low pressure steam turbines 16. Coal pulverizer 25. Cold-side Electrostatic precipitator
7. Boiler feedwater pump 17. Steam drum 26. Fan
8. Surface condenser 18. Bottom ash hopper 27. Flue gas desulfurization scrubber
9. Intermediate pressure steam turbine 19. Superheater 28. Flue gas stack
10. Steam control valve

Stack gas path and clean-up

For more information, see: Air preheater and Flue gas desulfurization.

As the combustion flue gas exits the steam generator, it flows through a heat exchange device where it is cooled by exchanging heat with the incoming combustion air. The device is called an air preheater. The gas exiting the steam generator is laden with particulate matter (PM), referred to as fly ash, which consists of very small ash particles. The flue gas contains nitrogen along with combustion products carbon dioxide (CO2), sulfur dioxide (SO2) and nitrogen oxides (NOx).

Various processes (known as De-NOx processes) are often used to reduce the amount of NOx in the flue gas before the flue gas exits the steam generator. After the exiting flue gas has been cooled by heat exchange with the combustion air, the fly ash in the flue gas is removed by fabric bag filters or electrostatic precipitators. Finally, after removal of the fly ash, many coal-fired power plants use one of the available flue gas desulfurization (FGD) processes to reduce sulfur dioxide emissions. The flue gas then exits to the atmosphere via tall flue gas stacks. A typical flue gas stack may be about 150 to 250 metres tall to disperse the remaining flue gas components in the atmosphere.

In the United States and a number of other countries, air pollution dispersion modeling[4] studies are required to determine the flue gas stack height needed to comply with the local air pollution regulations. The United States also requires the height of a flue gas stack to comply with what is known as the "Good Engineering Practice (GEP)" stack height.[5][6] In the case of existing flue gas stacks that exceed the GEP stack height, any air pollution dispersion modeling studies (to determine environmental impacts) for such stacks must use the GEP stack height rather than the actual stack height.

Supercritical steam generators

Above the critical point for water of 374 °C and 22 MPa, there is no phase transition from water to steam, but only a gradual decrease in density. Boiling does not occur and it is not possible to remove impurities via steam separation.

Supercritical steam generators operating at or above the critical point of water are referred to as once-through plants because boiler water does not circulate multiple times as in a conventional steam generator. Supercritical steam generators require additional water purification steps to ensure that any impurities picked up during the cycle are removed. This purification takes the form of high pressure ion exchange units called condensate polishers between the steam condenser and the feedwater heaters.

Conventional coal-fired power plants operate at subcritical conditions and typically achieve 34–36% thermal efficiency. Supercritical coal-fired power plants, operating at 565 °C and 243 bar (24.3 MPa) have efficiencies in the range of 38–40%. New "ultra critical" designs, operating at 700–720 °C and 365–385 bar (36.5–38.5 MPa), are expected to achieve 44–46% efficiency.[7]

Alternatives to coal-fired power plants

Alternatives to coal-fired power plants include using other fossil fuels (natural gas or fuel oil), nuclear power plants, geothermal power plants, hydroelectric power plants, solar power plants, wind power plants and tidal power plants.

Air pollution control technology

The major air pollutants emitted by coal-fired power plants are sulfur dioxide (SO2), nitrogen oxides (NOx), particulate matter (PM), and mercury (Hg).

Control of particulate matter emissions

The removal of particulate matter (referred to as fly ash) from the combustion flue gas is typically accomplished with electrostatic precipitators (ESP) or fabric filters. ESPs or fabric filters are installed on all power plants in the United States that burn pulverized coal. They routinely achieve 99% or greater fly ash removal.[7]

Typical particulate emissions from modern power plants in the United States that burn pulverized coal are less than 15 mg per cubic meter of flue gas (referenced at 0 °C and 101,325 kPa). New units in Japan are achieving 5 mg per cubic meter by using wet flue gas desulfurization units that also remove condensible particulates.[7]

Control of sulfur dioxide emissions

For more information, see: Flue gas desulfurization.

Partial flue gas desulfurization (FGD) can achieve about 50-70 % removal of sulfur dioxide by the injection of dry limestone just downstream of the air preheater. The resultant solids are recovered in the ESPs along with the fly ash.

In power plants burning pulverized coal, wet flue gas desulfurization (FGD) that contacts the flue gases with lime slurries (in what are called wet lime scrubbers) can achieve 95% sulfur dioxide removal without additives and 99+% removal with additives. Wet FGD has the greatest share of the FGD usage in the United States and it is commercially proven, well established technology.[7]

The typical older FGD units in power plants burning pulverized coal within the United States achieve average sulfur dioxide emission levels of about 0.340 kg/MWh (0.22 lb/106 Btu), which meets the level to which those units were permitted.

The lowest demonstrated sulfur dioxide emission level (in 2005) for power plants burning pulverized high-sulfur coal within the United States was 1.08 kg/MWh (0.07 lb/106 Btu) and 0.046 kg/MWh (0.03 lb/106 Btu) for plants burning low-sulfur pulverized coal.[7]

In 2006, power plants in the United States that burned fossil fuels (coal, fuel oil or natural gas) generated 327 GW of electric power, of which about 70% was generated in plants burning coal. Only about 30% of that 327 GW of generated power was derived from plants equipped with flue gas desulfurization.[8] The other 70% of the generated power was derived from power plants that met their permitted levels by burning low sulfur coals, fuel oil or natural gas.

In the 10 year period between 1996 and 2006, the sulfur dioxide emissions per year from coal-fired power plants in the United States declined from 12.9×106 metric tons to 9.5×106 metric tons which is a reduction of 26%. That decrease in sulfur dioxide emissions occurred despite the fact that the coal-fired power plant generation of electric power increased by 11%.[8]

In March 2005, the U.S. Environmental Protection Agency promulgated the Clean Air Interstate Rule (CAIR) which sets emission caps for particulate matter, sulfur dioxide and nitrogen oxides that are expected to result in more efficient FGD units being installed and more coal-fired power plants using FGD units or switching to burning oil or natural gas. The CAIR rules are still in litigation as of November 2008.[9]

Control of nitrogen oxides emissions

There are three technologies (known as De-Nox processes) available for reducing the emissions of NOx from combustion sources:[7]

  • The lowest cost combustion control technology for reducing NOx emissions is referred to as Lo-NOx and can acieve up to a 50% reduction in NOx emissions compared to uncontrolled combustion.
  • The most most effective, but most expensive, NOx emission reduction technology is Selective Catalytic Reduction (SCR). It can achieve 90% NOx reduction and is currently (2008) the technology of choice for achieving very low levels of NOx emissions.

The average NOx emissions from conventional coal-fired power plants in the United States typically range from about 0.14 kg/MWh (0.09 lb/106 Btu) to 0.20 kg/MWh (0.13 lb/106 Btu), which meets their permitted level of emissions.[7]

In 2005, the 20 lowest NOx emitting coal-fired power plants in the United States in 2005 achieved emission levels ranging from 0.06 kg/MWh (0.04 lb/106 Btu) to 0.10 kg/MWh (0.065 lb/106 Btu).[7]

In the 10 year period between 1996 and 2006, the NOx emissions per year from coal-fired power plants in the United States declined about 40% despite the fact that the coal-fired power plant generation of electric power increased by 11%.[8]

Control of mercury emissions

Mercury in the flue gas exists as both elemental and oxidized mercury vapor as well as mercury that has reacted with the fly ash.[10]

The removal of the fly ash in an ESP or a fabric filter also removes the mercury that has reacted with the fly ash, resulting in 10 to 30% removal for bituminous coals but less than 10% for sub-bituminous coals and lignite. The oxidized mercury vapor left in the flue gas after the fly ash removal is effectively removed by wet FGD scrubbing, resulting in 40-60% total mercury removal for bituminous coals and less than 30–40% total mercury removal for sub-bituminous coals and lignite.[7]

For low-sulfur sub-bituminous coals and particularly lignite, most of the mercury vapor is in the elemental form, which is not removed by wet FGD scrubbing. In most tests of bituminous coals, SCR (for NOx control) converted 85-95% of the elemental mercury to the oxidized form, which is then effectively removed by wet FGD scrubbing. With sub-bituminous coals, the amount of mercury remained low even with addition of an SCR.[7]

Additional mercury removal can be achieved by powdered activated carbon injection (PAC) and an added fiber filter to collect the carbon. This can achieve up to 85-95% removal of the mercury. Commercial short-duration tests with powdered, activated carbon injection have shown removal rates around 90% for bituminous coals but lower for sub-bituminous coals. For sub-bituminous coals, the injection of brominated, activated carbon has been shown to be highly effective in emissions tests at 3 power plants lasting 10 to 30 days with the potential to remove 90% removal of mercury.[7]

Ongoing research and development programs are evaluating improved technology that is expected to improve effectiveness. The general consensus in the industry is that this picture will change significantly within the next few years. The U.S. EPA states that they believe PAC injection and enhanced multi-pollutant controls will be available after 2010 for commercial application on most, if not all, key combinations of coal type and control technology to provide mercury removal levels between 60 and 90%. Optimization of this commercial multi-pollutant control technology by about 2015 should permit achieving mercury removal levels between 90 and 95% on most if not all coals, but the technology remains to be commercially demonstrated.[7]

In March 2005, the U.S. EPA issued the Clean Air Mercury Rule (CAMR), allocates a mercury emissions budget for each of the 50 states and other jurisdictions. If they so desire, the states can opt out of the EPA budget and implement a more stringent emissions reduction program than is required by CAMR.[11] As in the CAIR situation (see above section on control of sulfur dioxide emissions), the CAMR is currently (2008) still in litigation.[10]

Carbon dioxide emissions

Coal-fired power plants also emit large quantities of carbon dioxide (CO2) which is not a pollutant in the traditional sense. In fact, it is essential for all plant life on Earth through photosynthesis. However, it is a greenhouse gas considered to have a major role in so-called global warming.

(This section is still in development)

Emissions of radioactive nuclides

(This section is still in development)

References

  1. Pressurized deaerators
  2. Tray deaerating heaters
  3. EPA Workshop on Cooling Water Intake Technologies Arlington, Virginia John Maulbetsch, Maulbetsch Consulting Kent Zammit, EPRI. 6 May 2003. Retrieved 10 September 2006.
  4. Beychok, Milton R. (2005). Fundamentals Of Stack Gas Dispersion, 4th Edition. author-published. ISBN 0-9644588-0-2.  www.air-dispersion.com
  5. Guideline for Determination of Good Engineering Practice Stack Height (Technical Support Document for the Stack Height Regulations), Revised, 1985, EPA Publication No. EPA–450/4–80–023R, U.S. Environmental Protection Agency (NTIS No. PB 85–225241)
  6. Lawson, Jr., R. E. and W. H. Snyder, 1983. Determination of Good Engineering Practice Stack Height: A Demonstration Study for a Power Plant, 1983, EPA Publication No. EPA–600/3–83–024. U.S. Environmental Protection Agency (NTIS No. PB 83–207407)
  7. 7.00 7.01 7.02 7.03 7.04 7.05 7.06 7.07 7.08 7.09 7.10 7.11 Dr. James Katzer et al and MIT Coal Energy Study Advisory Committee (2007). The Future of Coal. Massachusetts Institute of Technology. ISBN 0-615-14092-0.  The Future of Coal
  8. 8.0 8.1 8.2 Electric Power Annual 2006
  9. Clean Air Interstate Rule
  10. 10.0 10.1 Clean Air Mercury Rule, Basic Information
  11. Clean Air Mercury Rule